controls.py - feedback control calculations (P, PD, PID).
Control theory keeps systems on target despite disturbances. These helpers compute a PID controller's output, characterise a second-order system's response (natural frequency, damping, overshoot), and simulate a closed loop so you can watch a controller settle - the kind of thing you would otherwise do in MATLAB's Control System Toolbox or Simulink.
Controls
P, PD, PID, and response-characterisation calculations.
Source code in fpc/controls.py
18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 | |
pid_output(*, error, integral, derivative, kp, ki=0.0, kd=0.0)
Single PID control output: u = Kpe + Kiintegral + Kd*derivative.
Set ki/kd to zero to get P or PD control - the same formula
covers all three controller types.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
error
|
current error e = setpoint - measurement |
required | |
integral
|
accumulated integral of the error over time |
required | |
derivative
|
rate of change of the error |
required | |
kp
|
proportional gain |
required | |
ki
|
integral gain, defaults to 0 (no integral action) |
0.0
|
|
kd
|
derivative gain, defaults to 0 (no derivative action) |
0.0
|
Returns:
| Type | Description |
|---|---|
|
controller output (command) u |
Source code in fpc/controls.py
21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 | |
damping_from_overshoot(*, percent_overshoot)
Damping ratio that produces a given step-response overshoot.
Inverts %OS = exp(-zeta*pi / sqrt(1-zeta^2)) * 100.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
percent_overshoot
|
desired overshoot [%] (e.g. 5 for 5%) |
required |
Returns:
| Type | Description |
|---|---|
|
required damping ratio zeta [-] |
Source code in fpc/controls.py
37 38 39 40 41 42 43 44 45 46 | |
settling_time(*, damping_ratio, natural_frequency, tolerance=0.02)
Approximate settling time of a second-order system.
t_s ~= -ln(tolerance) / (zeta * omega_n). The default 2% tolerance is the textbook convention.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
damping_ratio
|
damping ratio zeta [-] |
required | |
natural_frequency
|
undamped natural frequency omega_n [rad/s] |
required | |
tolerance
|
settling band as a fraction, defaults to 0.02 (2%) |
0.02
|
Returns:
| Type | Description |
|---|---|
|
settling time [s] |
Source code in fpc/controls.py
48 49 50 51 52 53 54 55 56 57 58 59 | |
simulate_pid_first_order(*, setpoint, time_constant, gain, kp, ki=0.0, kd=0.0, dt=0.01, duration=10.0)
Simulate a PID loop controlling a first-order plant.
The plant is tau * y' + y = gain * u (a motor, a heater, a tank...). We step it forward in time with a simple Euler integration so you can plot or inspect how the controlled output approaches the setpoint.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
setpoint
|
target value the controller should reach |
required | |
time_constant
|
plant time constant tau [s] |
required | |
gain
|
plant steady-state gain (output per unit input) |
required | |
kp
|
proportional gain |
required | |
ki
|
integral gain, defaults to 0 |
0.0
|
|
kd
|
derivative gain, defaults to 0 |
0.0
|
|
dt
|
simulation time step [s], defaults to 0.01 |
0.01
|
|
duration
|
total simulated time [s], defaults to 10 |
10.0
|
Returns:
| Type | Description |
|---|---|
|
tuple (time array [s], output array) as numpy arrays |
Source code in fpc/controls.py